Sharif Journal of Civil Engineering

Sharif Journal of Civil Engineering

Numerical Study of Cyclic Behavior of Steel Column Base Angle Connections Using Taguchi Experimental Design ­­

Document Type : Article

Authors
Department of Civil Engineering, University of Sistan and Baluchestan, Sistan and Baluchestan, Iran.
10.24200/j30.2025.66939.3430
Abstract
This study presents a numerical investigation into the cyclic behavior of steel column base connections equipped with replaceable yielding steel angles under cyclic loading conditions. Utilizing a combined methodology of finite element analysis through ABAQUS and the Taguchi design of experiments (DOE) approach, the research systematically evaluates the influence of three critical parameters: steel angle thickness, applied axial load ratio, and anchor bolt gauge distance from the column edge. The numerical model was rigorously validated against existing experimental results, demonstrating strong agreement and confirming its capability to accurately simulate the nonlinear hysteretic response of the connections. Nine strategically designed parameter combinations based on an L9 orthogonal array enabled an efficient exploration of the parameter space while capturing both individual and interactive effects. Statistical analysis via analysis of variance (ANOVA) identified the thickness of the steel angle as the most significant factor, accounting for approximately 59.43% of the variation in the maximum flexural moment capacity, followed by the gauge distance (24.95%) and axial load ratio (11.92%). The optimal parameter set—comprising a 10 mm angle thickness, 0.2 axial load ratio relative to column capacity, and 40 mm gauge distance—yielded a peak flexural moment capacity of 30.71 kN·m, closely matching the finite element prediction of 30.56 kN·m. Hysteresis curve analyses reveal enhanced energy dissipation capacity, increased initial stiffness, and improved ductility in the optimized configuration, although the connection behavior consistently remains within the pinned range as per ANSI/AISC 360-16 specifications. The concentrated plasticity in the replaceable angle elements effectively localizes damage, promoting easy post-earthquake repair without compromising the main structural components. A regression model derived from the DOE results facilitates reliable predictions of flexural capacity based on the aforementioned parameters, underscoring the practical utility of the Taguchi method in seismic design optimization. These findings provide critical insights into the design of resilient, low-damage steel column base connections capable of sustaining seismic demands while enhancing reparability and lifecycle performance.
Keywords
Subjects

 
1.Kanvinde, A.M., Jordan, S.J. and R.J. Cooke., 2013. Exposed column base plate connections in moment frames — Simulations and behavioral insights. Journal of Constructional Steel Research. 84: p. 82-93.DOI: 10.1016/j.jcsr.2013.02.015.
2.Lim, W. Y., Lee, D. and You, Y. C., 2017. Exposed column-base plate strong-axis connections for small-size steel construction. Journal of Constructional Steel Research. 137, pp. 286-296.DOI: 10.1016/j.jcsr.2017.06.018.
3. Sivandi-Pour, A., G‌e‌r‌a‌m‌i, M. and T‌a‌g‌h‌d‌i‌s‌i, M., 2019. A‌s‌s‌e‌s‌s‌m‌e‌n‌t o‌f t‌h‌e e‌f‌f‌e‌c‌t o‌f c‌o‌l‌u‌m‌n b‌a‌s‌e conn‌e‌c‌t‌i‌o‌n r‌o‌t‌a‌t‌i‌o.DOI: 10.24200/j30.2018.2132.2103.
4.Pachideh, G., Gholhaki, M. and Moshtagh, A., 2021. An experimental study on cyclic performance of the geometrically prismatic concrete-filled double skin steel tubular (CFDST) columns. Iranian Journal of Science and Technology, Transactions of Civil Engineering, 45(2), pp. 629-638.DOI: 10.1007/s40996-020-00410-z.
5.Pachideh, G., Gholhaki, M. and Moshtagh, A., 2021. Impact of temperature rise on the seismic performance of concrete-filled double skin steel columns with prismatic geometry. Journal of Testing and Evaluation, 49(4), pp. 2800-2815.DOI: 10.1520/jte20200037.
6.Aghaei, I. and Miri, M., 2023. Experimental and analytical investigation of asymmetric friction connections in steel column bases. 13th International Congress on Civil Engineering, [in Persian].   https://civilica.com/doc/1853046.
7.Zhang, R., Liu, J., Xu, J. and Jia, L., 2024. Low-damage performance of blast resilient steel rocking column base with friction connection. Thin-Walled Structures, 197, pp. 111598.DOI: 10.1016/j.tws.2024.111598.
8.Zhang, R., Xie, J., Chouery, K., Liu, J., Jia, L., Xiang, P., Zhao, X., MacRae, G., Clifton, G. C., Dhakal, R., Ramhormozian, S. and Yan, Z., 2022. Strong axis low-damage performance of rocking column-base joints with asymmetric friction connections. Journal of Constructional Steel Research, 191, pp. 107175.DOI: 10.1016/j.jcsr.2022.107175.
9.Zhang, R., Yan, Z., Xie, J., Liu, J., Jia, L., Xiang, P., Zhao, X., MacRae, G., Clifton, G. C., Dhakal, R. and Ramhormozian, S.,  2024. Weak axis low-damage performance of seismic resilient rocking steel column base with friction connection. Journal of Building Engineering, 86, pp. 108778.DOI: 10.1016/j.jobe.2024.108778.
10.     Kamperidis, V.C., Karavasilis, T.L. and Vasdravellis, G., 2018. Self-centering steel column base with metallic energy dissipation devices. Journal of Constructional Steel Research, 149, pp. 14-30. DOI:10.1016/j.jcsr.2018.06.027.
11.Shen, P., Yang, P., Chen, Y., Yang, Y. and Zhou, J., 2024. Seismic performance of self-centering steel column base with buckling-restrained bars. Journal of Building Engineering, 91, pp. 109474.
DOI: 10.1016/j.jobe.2024.109474.‌n‌a‌l s‌t‌i‌f‌f‌n‌e‌s‌s o‌n s‌e‌i‌s‌m‌i‌c b‌e‌h‌a‌v‌i‌o‌r o‌f t‌h‌e s‌t‌e‌e‌l m‌o‌m‌e‌n‌t f‌r‌a‌m‌e‌s. Sharif Journal of Civil Engineering, 35(2.1), p. 83-92. [in Persian].
12.G‌e‌r‌a‌m‌i, M. and K‌h‌a‌t‌a‌m‌i, M., 2017. Th‌e e‌f‌f‌e‌c‌t‌s o‌f i‌n‌i‌t‌i‌a‌l p‌o‌s‌t t‌e‌n‌s‌i‌o‌n‌i‌n‌g f‌o‌r‌c‌e o‌n s‌e‌i‌s‌m‌i‌c b‌e‌h‌a‌v‌i‌o‌r o‌f s‌t‌e‌e‌l m‌o‌m‌e‌n‌t r‌e‌s‌i‌s‌t‌i‌n‌g f‌r‌a‌m‌e‌s b‌y p‌o‌s‌t-t‌e‌n‌s‌i‌o‌n‌e‌d c‌o‌n‌n‌e‌c‌t‌i‌o‌n‌s. Sharif Journal of Civil Engineering. 33(1.1), pp. 107-115. [in Persian]. DOI: 10.24200/j30.2017.1101.
13.Li, Y. W. and Koetaka, Y., 2022. Steel rocking column bases with replaceable cover plates: Cyclic loading behaviour and practical design. Engineering Structures, 264, pp. 114467.DOI: 10.1016/j.engstruct.2022.114467.
14.Wang, B., Zhu, S., Chen, K., Qiu, C.X. and Chen, P., 2024. Damage-free self-centering steel columns incorporating SMA bolts and replaceable steel angles. Engineering Structures, 321, pp. 119000.DOI: 10.1016/j.engstruct.2024.119000.
15.Wang, X. T., Xie, C.T., Lin, L.L. and Li, J., 2019. Seismic behavior of self-centering concrete-filled square steel tubular (CFST) column base. Journal of Constructional Steel Research, 156, pp. 75-85.DOI: 10.1016/j.jcsr.2019.01.025.
16.Xiao, G., Wang, H., Pan, P., Pan, H., He, R. and Tian, G., 2024. Development of self-centering and energy-dissipating dual-stage reinforced concrete rocking column-base system. Engineering Structures, 321, pp. 118943.DOI: 10.1016/j.engstruct.2024.118943.
17.Borzouie, J., 2015. low damage steel base connection. University of Canterbury, Christchurch, New Zealand.
18.Hou, H., Wang, C., Qu, B. and Liang, Y., 2021. Cyclic testing of bolted base connections for wide-flange columns. Engineering Structures, 235, pp. 112024.DOI: 10.1016/j.engstruct.2021.112024.
19.B‌a‌g‌h‌e‌r‌i, S. and V‌a‌f‌i T‌a‌b‌r‌i‌z‌i, N., 2014. Ev‌a‌l‌u‌a‌t‌i‌o‌n o‌f p‌a‌r‌t‌i‌a‌l r‌i‌g‌i‌d‌i‌t‌y o‌f s‌i‌m‌p‌l‌e s‌t‌e‌e‌l f‌r‌a‌m‌e‌s w‌i‌t‌h a‌n‌g‌l‌e c‌o‌n‌n‌e‌c‌t‌i‌o‌n‌s u‌n‌d‌e‌r g‌r‌a‌v‌i‌t‌y l‌o‌a‌d‌s. Sharif Journal of Civil Engineering, 30(1.2), pp. 137-146. [in Persian].
20.Tarighi, P., Kafi, M.A. and Vahdani, R., 2024. Experimental investigation of the performance of replaceable-rigid connection. Sharif Journal of Civil Engineering, 39(4), pp. 3-17. [in Persian].
21.Hou, H., Sun, B., Qu, B., Wang, C., Zhang, S. and Liang, Y., 2021. Testing of bolted base connections for wide-flange columns under combined axial compression and weak-axis lateral forces. Journal of Constructional Steel Research, 179, pp. 106547.DOI: 10.1016/j.jcsr.2021.106547.
22.Meng, B., Du, Q., Zhong, W., Tan, Z. and You, K.,  2024. Performance analysis of novel double web V-bending angle-steel connections against progressive collapse. Structures, 59, pp. 105705.DOI: 10.1016/j.istruc.2023.105705.
23.Sun, D., Yang, Y., Miao, J., Feng, S. and Xue, W., 2024. Moment-rotation model of self- centering (SC) column base with web-friction-device (WFD) and stiffener-steel (SS) angles. Journal of Constructional Steel Research, 219, pp. 108801.DOI: 10.1016/j.jcsr.2024.108801.
24.Sun, D., Yang, Y., Ma, Y., Xue, Y., Yu, Y. and   Feng, S., 2022. Seismic behavior of self-centering column base with replaceable stiffener angle steels. Thin-Walled Structures, 181, pp. 110113.DOI: 10.1016/j.tws.2022.110113.
25.Aabid, A., Ibrahim, Y., Hrairi, M. and Ali, J.S.M.,  2023. Optimization of structural damage repair with single and double-sided composite patches through the finite element analysis and taguchi method. Materials, 16(4), pp. 1581.DOI: 10.3390/ma16041581.
26.Mohammad Bagheri, S., Naderi, M., Vajdi, M.,  Sadegh Moghanlou, F. and Tarlani Beris, A., 2023. Numerical optimization of sample and die geometric parameters to increase the attainable temperature during spark plasma sintering of TiC ceramics. Synthesis and Sintering, 3(4).DOI: 10.53063/synsint.2023.34179.
27.Sharifi, H., Adib, A., Ahmadi, Z., Gemikonakli, E. and Shahedi Asl, M., 2024. Taguchi optimization of mask stereolithographic 3D printing parameters for tensile strengthening of functionally graded resins. International Journal on Interactive Design and Manufacturing (IJIDeM), 18(7), pp. 4899-4910.DOI: 10.1007/s12008-024-01839-6.
28.Abaqus, F., 2014. ABAQUS 6.14 Documentation. Dassault Syst Provid Google Scholar, 12, pp. 129-130.
29.Wei, J. P., Tian, L.M., Guo, Y., Qiao, H.Y., Jiao, Z.A. and Bao, Y., 2022. Design and cyclic behavior of a bidirectional double-hinge steel column base. Structures, 43, pp. 1573-1591.DOI: 10.1016/j.istruc.2022.07.052.
30.He, X., Ke, K., Guo, L., Yam, M.C.H. and Wang, Z., 2021. A replaceable fuse steel-concrete composite connection: Force transfer mechanism and design considerations. Journal of Constructional Steel Research, 183, pp. 106760.DOI: 10.1016/j.jcsr.2021.106760.
31.AISC 341, 2016. Seismic provisions for structural steel buildings, ANSI/AISC. American Institute of Steel Construction. Chicago, IL.
32.ASCE 41, 2017. Seismic evaluation and retrofit of existing buildings, Standard ASCE/SEI 41-17. American society of civil Engineers, pp. 623.
33.AISC 360, 2016. Specification for structural steel buildings (ANSI/AISC 360-16). American Institute of Steel Construction, Chicago, IL.